Cable for security and fire alarm systems

Cable for security and fire alarm systems

J-Y(St)Y Lg

Shielded signal cable

Structure Application Characteristics

Shielded signal cable for fire alarm, single core, screen - aluminum foil + ground wire, PVC sheath, 300 V, 1-10 pairs, diameter - 0.6-1.38 mm.

Cable structure:

  • Uncoated copper conductors, mono
    Core insulation – PVC compound, YI1;
  • Core marking according to TU
  • Core twisted in pairs
  • Pairs are braided in layers with constant twisting steps
  • Screen – tinned copper wire together
  • Grounding wire diameter – up to 10 pairs = 0.4 mm, from 10 pairs = 0.6 mm
  • Outer sheath made of PVC compound,
  • Sheath color red

Fire alarm cables J-Y(St)Y...Lg are used in building communication systems as fire warning cables. The shielded fire alarm cable can be used in special areas where a tight bend radius over a short distance is required.

  • Number of cores: from 1 to 10 pairs
  • Diameter: from 0.6 to 1.38 mm
  • Operating temperature: from -30°C to +70°C
  • Insulation resistance, min.: 100 MOm/km
  • Effective unbalance (800 Hz), max.: 100 nF/m
  • Capacitive unbalance (k), min.: 300 pF/100m
  • Operating voltage, peak: 300 V
  • Test voltage (AC 50 Hz):

- core / core - 800 В

- core / shield - 800 В

  • Minimum cable bending radius: 10 x cable Ø

Compliance with fire safety standards

 

Name

 

Number of cores / Ø, mm

External. Ø, мм

Copper weight kg/km

Cable weight kg/km

J-Y(St)Y Lg 1x2x0,60 мм

1x2xØ0,60

4,4

6,7

28

J-Y(St)Y Lg 2x2x0,60 мм

2x2xØ0,60

4,9

12,22

38

J-Y(St)Y Lg 3x2x0,60 мм

3x2xØ0,60

5,9

17,74

51

J-Y(St)Y Lg 4x2x0,60 мм

4x2xØ0,60

6,5

23,26

62

J-Y(St)Y Lg 5x2x0,60 мм

5x2xØ0,60

7

28,78

73

J-Y(St)Y Lg 6x2x0,60 мм

6x2xØ0,60

7,5

34,3

83

J-Y(St)Y Lg 8x2x0,60 мм

8x2xØ0,60

8,3

45,34

103

J-Y(St)Y Lg 10x2x0,60 мм

10x2xØ0,60

9

56,38

122

J-Y(St)Y Lg 1x2x0,80 мм

1x2xØ0,80

5,4

14,61

44

J-Y(St)Y Lg 2x2x0,80 мм

2x2xØ0,80

6,1

24,61

63

J-Y(St)Y Lg 3x2x0,80 мм

3x2xØ0,80

7,6

34,67

86

J-Y(St)Y Lg 4x2x0,80 мм

4x2xØ0,80

8,4

44,61

105

J-Y(St)Y Lg 5x2x0,80 мм

5x2xØ0,80

9,2

54,59

124

J-Y(St)Y Lg 6x2x0,80 мм

6x2xØ0,80

9,8

64,55

143

J-Y(St)Y Lg 8x2x0,80 мм

8x2xØ0,80

11

85,61

179

J-Y(St)Y Lg 10x2x0,80 мм

10x2xØ0,80

12,5

104,39

228

J-Y(St)Y Lg 12x2x0,80 мм

12x2xØ0,80

13,4

126,61

264

J-Y(St)Y Lg 16x2x0,80 мм

16x2xØ0,80

15,1

167,61

335

J-Y(St)Y Lg 20x2x0,80 мм

20x2xØ0,80

16,6

203,99

404

КСВВ

КАБЕЛЬ ДЛЯ СИГНАЛІЗАЦІЇ І ОХОРОНИХ СИСТЕМ

Structure Application Characteristics

Conductive copper single core

Insulation: polyvinyl chloride (PVC)

Sheath: polyvinyl chloride (PVC)

Cable for signaling and security systems with copper single-wire conductors insulated with polyvinyl chloride (PVC), twisted together, in a common polyvinyl chloride (PVC) sheath. The outer sheath of the cable has no filling and is made in the form of a tube.

KSVV cables are designed for connecting intercoms, transmitting low-power electrical signals with alternating voltage up to 250 V, frequency up to 1000 Hz or direct voltage up to 350 V. They are used for laying in rooms, channels, in the absence of mechanical influences on the cable.

Main technical characteristics: Rated voltage up to 250 V. Test voltage of alternating current with a frequency of 50 Hz for 1 min. 1500 V. Cables are operated in a stationary state at an ambient temperature from minus 500C to plus 500C, with a relative humidity of up to 98% at a temperature of up to 350C. cables during laying and installation - not less than 15 external cable diameters. The long-term permissible heating temperature of the cores during operation should not exceed 700C. The number of cores in the cable: 2; 4; 6; 8; 10; 12; 14; Conductor design: corresponds to class 1 and 3 Cables do not spread combustion when laid alone Construction length of cables: not less than 100 m. Marking of insulated cores: all insulated cores differ in color from each other. Color marking can be solid or in the form of longitudinal stripes.

Packaging: coils or wooden drums.
Cable service life – not less than 15 years.

Name:

2*0,4 мм ксвв

4*0,4 мм ксвв

6*0,4 мм ксвв

8*0,4 мм ксвв

10*0,4 мм ксвв

12*0,4 мм ксвв

14*0,4 мм ксвв

16*0,4 мм ксвв

18*0,4 мм ксвв

20*0,4 мм ксвв

ALARM CABLE Cu Shielded

Structure Application Characteristics

Signal Cable Copper Shielded
ALARM CABLE Cu Shielded

Signal cable is used in security systems, telephone systems, fire alarm systems, as well as when connecting intercoms. Such cables have found their application in the installation of security and fire alarms, access control systems, intercom systems, etc.

Alarm signal cable, used in low-current security and communication systems. The cable is made of copper with a different number of cores.

The main parameter when choosing a signal cable for low-current systems is the ohmic resistance of the cable. With power wires, it is better to use a shielded signal cable. Also, one of the main criteria for the cable is the number of conductive cores.

The minimum cable is 2 * 0.22, and the maximum is 20 * 0.22 mm.

Model

Description:

2*0,22мм Shielded

2-wire signal cable, multi-core,

(2*0,22mm) white 100м.

4*0,22мм Shielded

4-wire signal cable, multi-core,

(4*0,22mm) white 100м.

6*0,22мм Shielded

6-wire signal cable, multi-core,

  (6*0,22mm) white 100м.

8*0,22mm Shielded

8-wire signal cable, multi-core,

(8*0,22mm) white 100м.

10*0,22мм Shielded

10-wire signal cable, multi-core,

(10 * 0,22mm) white 100м.

12*0,22мм Shielded

12-wire signal cable, multi-core,

(12 * 0,22mm) white 100м.

14*0,22мм Shielded

14-wire signal cable, multi-core,

(14 * 0,22mm) white 100м.

16*0,22мм Shielded

16-wire signal cable, multi-core,

  (16 * 0,22mm) white 100м.

18*0,22мм Shielded

18-wire signal cable, multi-core,

(18 * 0,22mm) white 100м.

20*0,22мм Shielded

20-conductor signal cable, multi-core,

(20 * 0,22mm) white 100м.

ALARM CABLE Cu Unshielded

Structure Application Characteristics

Alarm Сигнальний кабель Мідний Неекранований
ALARM CABLE
Cu Unshielded

Signal cable is used in security systems, telephone systems, fire alarm systems, as well as when connecting intercoms. Such cables have found their application in the installation of security and fire alarms, access control systems, intercom systems, etc.

Alarm signal cable, used in low-current security and communication systems. The cable is made of copper with a different number of cores.

The main parameter when choosing a signal cable for low-current systems is the ohmic resistance of the cable. If you will use the cable next to power wires, it is best to use a shielded signal cable. Also, one of the main criteria for the cable is the number of conductive cores.

The minimum cable is 2 * 0.22 mm, and the maximum is 20 * 0.22 mm.

Model

Description

2*0,22мм Unshielded

2-wire signal cable, multi-core,

(2*0,22mm) white 100м.

4*0,22мм Unshielded

4-х провідний кабель сигнальний, багатожильний,

(4*0,22mm) білий 100м.

6*0,22мм Unshielded

6-провідний кабель сигнальний, багатожильний,

  (6*0,22mm) білий 100м.

8*0,22mm Unshielded

8-провідний кабель сигнальний, багатожильний,

(8*0,22mm) білий 100м.

10*0,22мм Unshielded

10-ти провідний кабель сигнальний, багатожильний,

(10 * 0,22mm) білий 100м.

12*0,22мм Unshielded

12-ти провідний кабель сигнальний, багатожильний,

(12 * 0,22mm) білий 100м.

14*0,22мм Unshielded

14-ти провідний кабель сигнальний, багатожильний,

(14 * 0,22mm) білий 100м.

16*0,22мм Unshielded

16-ти провідний кабель сигнальний, багатожильний,

  (16 * 0,22mm) білий 100м.

18*0,22мм Unshielded

18-ти провідний кабель сигнальний, багатожильний,

(18 * 0,22mm) білий 100м.

20*0,22мм Unshielded

20-ти провідний кабель сигнальний, багатожильний,

(20 * 0,22mm) білий 100м.